TROC™
oxy-combustion

Solid fuels react with oxygen under pressure, in a chemical reactor that produces heat without a flame. Reliable power, with CO₂ leaving as a concentrated stream.

CO₂ capture
99.4%
SO₂ and NOxBelow U.S. federal limits
99.8%
  • No flame
  • No smokestack
  • Simplified plant footprint
  • No internal moving parts

Process

The TROC™ island in elevation: air separation, fuel feed, the combustor loop, gas cooler, candle filter, condenser, CO₂ dryer and compressor, and the steam turbine.
  1. Feed

    Dry solid fuel and oxygen, under pressure

    Turndown
    25:1
    Moving parts
    None
  2. Combustion

    Flameless, in a circulating bed of hot solids

    Temperature
    871–899 °C
    Carbon conversion
    99.8%
  3. Steam

    Raised by heat exchangers inside the solids loop

    Supercritical conditions
    245 bar, 585 °C
    Recycle gas for cooling
    None
  4. Filtration

    Sintered-metal candles, at process pressure

    Particulate downstream
    <2 ppmw
    Solids collection
    99.9999%
  5. Water

    Condensed out of the gas under pressure, and reused

    Liquid discharge
    Zero
    Share of plant make-up
    ~10%
  6. CO₂

    Dried, and ready for transport or use

    Product purity
    95%+
    Carbon captured
    99.4%

No smokestack.

SO₂ and NOx against U.S. federal limits
99.8% below
Combustion gas vented in normal operation
<1%

CO₂ capture

Fuel and oxygen react in a bed of hot solids, without a flame, and the gas that leaves is carbon dioxide and water vapor. The water is condensed out, and the carbon dioxide is dried and compressed for transport or use.

CO₂ per MWh, dried and compressed
1 t
CO₂ a year from one 500 MWe unit
2.8 Mt
Purity, to pipeline specification
95%+

Carbon intensity

Plant Net CO₂, kg per MWh
Coal-fired, U.S. average
1,048
Gas-fired, U.S. average
435
Gas combined cycle with capture
30
TROC™ on coal
6
TROC™ with 10% biomass
−95
TROC™ with 20% biomass
−197
TROC™ with 30% biomass
−298

CO₂ to the atmosphere at the plant, with the carbon in biomass counted as taken from the air; biomass by share of heat input. Fleet averages are from the U.S. Energy Information Administration (2023); gas with capture from the Global CCS Institute (2026).

Emissions

Sulfur and NOx are controlled in the bed, without SCR or FGD.

SO₂
0.17% of the limit0.0017 of 1.00 lb/MWh
NOx
0.17% of the limit0.0012 of 0.70 lb/MWh
Particulate
0.03% of the limit0.000023 of 0.09 lb/MWh
Hydrogen chloride
3.1% of the limit0.00031 of 0.010 lb/MWh

Modeled emissions per gross MWh, against U.S. MATS and NSPS limits for coal-fired units.

Performance

Gross efficiency (HHV), supercritical
44.4%
Combustor turndown
5:1
Ramp rate, per minute
4%

TROC™ figures are from engineering models and pilot-scale combustion testing.

Fuels

  • Bituminous coal
  • Sub-bituminous coal
  • Lignite
  • Petroleum coke
  • Biomass
  • Refuse-derived fuel

Biomass

Up to 100% of the heat input, and net-negative CO₂ from a few percent

High-sulfur fuels

Up to 99.7% captured in the bed, tested to 5.3% in the feed

High-ash coal

Up to 60% by weight, discharged dry

Repowering

  1. Replaced

    Boiler, SCR, FGD, and stack

  2. Kept

    Fuel handling, steam turbine and generator, cooling, and grid connection

  3. Saved

    Construction time, capital, permitting, and the wait for a grid connection

Why repower

Time to construction

The site, turbine hall, and cooling system are standing, so work starts at the reactor island

Capital

Fuel handling, the steam turbine and generator, cooling, and plant electrical equipment are reused

Permitting

An existing power plant site, with emissions far below those of the unit it replaces

Grid interconnection

The generator stays on the lines it already feeds. A new project in the United States takes more than five years from its request to operation

Time from interconnection request to commercial operation is from Lawrence Berkeley National Laboratory (2026).

Retiring coal

More than a quarter of the U.S. fleet is planned to close by 2030. Each site has the turbine, cooling water, and grid connection a TROC™ unit needs.

Retired from 2017 to 2025
87 GW
Scheduled to retire in 2026
6.4 GW
Units of 500 MWe to repower what retires by 2030
100+

Jobs

Biomass
11.5
Coal
6.9
Nuclear
5.0
Natural gas
4.4
Wind
3.6
Solar
3.6

U.S. jobs per megawatt-year of electricity, across fuel supply, construction, equipment, and operations, from Idaho and Oak Ridge National Laboratories (2024); nuclear is the mean of two cases, biomass is with carbon capture. Fleet and retirements are from the American Public Power Association (2026) and the U.S. Energy Information Administration (2026).

Economics

Engineering models put TROC™ power among the least costly near-zero-emissions generation, and significantly below new nuclear.

Levelized cost of electricity LowerHigher
TROC™
Nuclear
Gas combined cycle with capture
Solar with storage
Wind with storage
Geothermal

What TROC™ adds

Modules of 100 to 500+ MWe, on existing sites
Against nuclear
Capture built in, at 99.4%
Against gas combined cycle with capture, at 90–95%
Dispatchable around the clock
Against solar with storage
Dispatchable in any weather
Against wind with storage
Sited where the power is needed
Against geothermal

New generation in the United States, each technology with the federal tax credit open to it. The alternatives are from Lazard’s LCOE+ (2026), whose storage cases pair generation with a four-hour battery at half the plant’s rating; gas with capture adds capture costs from the Global CCS Institute (2026). TROC™ is from engineering models, on Powder River Basin coal.

Operating basis

The combustor is built on the transport reactor at the core of TRIG™, with heat exchangers added to its solids loop.

Hours on the transport reactor, in combustion and gasification
35,000
Hours as a pressurized combustor at pilot scale
5,000
Commercial IGCC facility running two reactors of comparable size
582 MW

TRIG™ operating record

Project inquiries

Contact us